Dispenser
1. Main Technic Index
|
Type of product
|
Single and dual hose
|
|
Measuring accuracy
|
±0.5%
|
|
Flow range
|
1~30 m3/min or 2~40 m3/min
|
|
Rated pressure
|
20MPa
|
|
Max. working pressure
|
25MPa
|
|
Compressive strength
|
37.5MPa
|
|
Environment temperature
|
-45°C~+50°C
|
|
Explosion proof grade
|
ExdemibⅡAT4
|
|
Power supply
|
220V±15% 50Hz±1Hz
|
|
Min. reading value
total memory
|
0.01 m3 0.01RMB
|
|
Single volume range
|
0~9999.99 m3/RMB
|
|
Totalizers
|
0~999999.99 m3/RMB
|
|
Unit Price prefab range
|
0.01~99.99 RMB /m3
|
|
Density prefab range
|
0.0001~0.9999
|
|
Prefab quantity range
|
1~9999N m3 or 1~9999RMB
|
|
Dual LCD
|
Price(RMB /m3) Volume(m3) Sale(RMB)
|
|
Breakaway coupling power
|
≤400N
|
|
Rated power
|
﹤200W
|
|
Mass flow meter
|
Imported mass flow meter with temperature sensor for compensating
|
2. Basic function
1) The electricity controls system which has an independent intellectual property right
2) Filling process control automatically, displaying unit price, quantity and value with dual LCD(backlighting) during filling process
3) Three line pressure switching automatically, which assures taking out CNG from cylinder cascades accurately and effectively
4) Displaying unit price, quantity and value ,having pressure gauge to display pressure
5) Saving data automatically after power cut, displaying data lingeringly
6) Having great memory capacity, can inquire 4,000 times filling data and three years?data if connecting with computer;
7) Monitor system: monitoring the temperature, pressure and flow in filling process to control the filling speed;
8) Filling control system: controlling taking out gas from cylinder cascades to assure the max. filling flow;
9) Inner imported American time system to assure timing accurately;
10) Pressure protection function: stopping filling automatically when the filling pressure is higher than the ruled value;
11) Inquiring CNG accumulative total amount at any time;
12) Presetting CNG quantity and sale value function;
13) Modifying the filling pressure and CNG density;
14) Having breakaway coupling and inlet ball valves;
15) Re-displaying the recent filling data;
16) Monitoring malfunction automatically and displaying malfunction code function
17) Displaying pressure directly during filling process, pressure can be modified
18) Filling hose having breakaway protection function;
19) Having pressure discharge and blow-off function;
20) Having manual emergency shut-down valve function;
21) Cleaning filter online without disassembly
22) Shutting machine automatically when measure signal cable broken off, which can prevent stealing CNG purposely
23) Assembling dispenser computer managing system according as customer? request
24) Assembling bill printer according as customer? request
25) Having IC card presetting port and computer managing system;
26) Having communication port, this can connect with computer.